Volume : 09, Issue : 04, April – 2022

Title:

09.THE ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE SIMULTANEOUS ESTIMATION OF IMIPENEM & CILASTATIN BY USING RP- HPLC
‏‬

Authors :

Chekuri Meghana, Pondari Rashmitha, Baddem Bhargavi, Dantukurthi Lalitha, Ch. Madhu

Abstract :

A new method was recognized for simultaneous estimation of Imipenem and cilastatin by RP-HPLC method. The chromatographic circumstances were effectively developed for the separation of Imipenem and cilastatin by using SYMMETRYC18 column (4.6×150mm)5µ, flow rate was 1ml/min, mobile phase ratio was (70:30 v/v) methanol:phosphate buffer(KH2PO4and K2HPO4) pH 3 ( pH was adjusted with orthophosphoricacid),detectionwavelength was 258nm. The instrument used was WATERS HPLC Auto Sampler, Separation module 2695, photo diode array detector 996, Empower-software version-2. The retention times was found to be 3.345 mins and 2.523 mins. The percentage purity of Imipenem and cilastatin was initiate to be 100.27% and 99.87% correspondingly.The system suitability parameters for Imipenem and cilastatin such as theoretical plates and tailing factor was found to be 2885, 1.25 and 2235 and 1.33, the resolution were found to be3.48. The analytical technique was validated according to ICH guidelines (ICH, Q2 (R1)). The linearity study n Imipenem and cilastatinwere found in concentration range of 50µg-250µg and 5µg-50µg and correlation coefficient (r2) was found to be 0.999 and 0.999, % recovery were found to be 99.56% and 99.48%, %RSD for repeatability was 1.2 and 2, % RSD for intermediate precision was 1.1 and 1.1 respectively. The precision study was precise, robust, and repeatable.LOD value was 0.03 and 2.17,and LOQ value was 0.11 and 6.6 respectively.
Keywords: Imipenem , cilastatin , precise, robust, and repeatable

Cite This Article:

Please cite this article in press Chekuri Meghana et al, The Analytical Method Development And Validation For The Simultaneous Estimation Of Imipenem & Cilastatin By Using RP- HPLC., Indo Am. J. P. Sci, 2022; 09(4).,

Number of Downloads : 10

References:

1. Herman G, Bergman A, Liu F, Stevens C, Wang A, Zeng W, Chen L, Snyder K, Hilliard D, Tanen M, Tanaka W, Meehan A, Lasseter K, Dilzer S, Blum R, Wagner J. Pharmacokinetics and pharmacodynamic effects of the oral DPP-4 inhibitor Imipenem in middle-aged obese subjects. J.Clin.Pharmacol.2006; 46 (8): 876–886.
2. Dubal Anil, KhatwalRizwanbasha ,KosarajuJayasankar, MedaVenkat, Samanta Malay. Bioanalytical method development and validation of Imipenem by RP-HPLC and its application to pharmacokinetic study. Int. J. Pharm Pharm Sci.2012; 4, (2): 691-694.
3. BalaSekaran C, Prameela Rani A. Development and Validation of spectrophotometric method for the determination of DPP-4 Inhibitor, Imipenem, in its pharmaceutical preparations. Int. J. Pharm. Pharm. Sci.2010; 2(4): 138-142.
4. Parag Pathade, Imran Md, Vinod Bairagi,YogeshAhire. Development and Validation of Stability Indicating UV Spectrophotometric Method for the Estimation of Imipenem in Bulk and Tablet Dosage Form. J. Pharm. Res. 2011; 4(3): 871-873.
5. Ghazala Khan, Dinesh SahuAgrawal Y P, NeetuSabarwal, AvnishJain,Gupta A K. Simultaneous Estimation of Cilastatin and Imipenem In Tablet Dosage Form. Asian J. Biochem. Pharma. Res. 2011; 1(2): 352-358.
6. Ramzia El-Bagary I, EhabElkady F, BassamAyoub M. Spectroflourometric and Spectrophotometric Methods for the Determination of Imipenem in Binary Mixture with Cilastatin and Ternary Mixture with Cilastatin and Imipenem Alkaline Degradation Product. Int. J. Biomed. Sci.2011; 7(1): 62-69.
7. Ravi PratapPulla, Sastry B S, Rajendra Prasad Y, AppalaRaju N. Simultaneous Estimation of Cilastatinand Imipenem Phosphate in Tablet Dosage Forms by RP-HPLC. Res. J. Pharm. Tech. 2011; 4(4): 646-649.
8. Shyamala M, Mohideen S, Satyanarayana T, Narasimha Raju Ch, Suresh Kumar P, SwethaK. Validated RP-HPLC for simultaneous estimation of Imipenem andcilastatinin tablet dosage form. American J. Pharm Tech. Res. 2011; 1(2): 93-101.
9. Zeng W, Xu Y, Constanzer M, Woolf EJ. Determination of Imipenemin human plasma using protein precipitation and tandem mass spectrometry. J.Chromatogr. B. 2010; 878(21):1817-1823.
10. Wei Zeng, Donald Musson G, Alison Fisher L, Li Chen, Michael Schwartz S, Eric Woolf J, Amy Qiu Wang. Determination of cilastatin in human urine and hemodialysate using turbulent flow online extraction and tandem mass spectrometry. J. Pharm. Biomed.Anal.2008; 46(3): 534-542.