Volume : 09, Issue : 12, December – 2022

Title:

89.METHOD DEVELOPMENT AND VALIDATION FOR MEROPENEMAND VABORBACTAM BY RP-HPLC METHOD

Authors :

D.Vaishnavi, Dr V.Kiran Kumar

Abstract :

A simple, Accurate, precise method was developed for the simultaneous estimation of the Meropenem and Vaborbactam in Tablet dosage form. Chromatogram was run through Inertsil ODS C185m (4.6 x 250mm). Mobile phase containing Phosphate buffer and Acetonitrile in the ratio of 30:70 was pumped through column at a flow rate of 1ml/min. Buffer used at pH 4.6. Temperature was maintained at Ambient. Optimized wavelength for Vaborbactam and Vaborbactam was 260nm. Retention time of Meropenem and Vaborbactam were found to be 2.395min and 3.906min. The % purity of Meropenem and Vaborbactam was found to be 100.6% and 101.3% respectively. The system suitability parameters for Meropenem and Vaborbactam such as theoretical plates and tailing factor were found to be 1.3, 1012.4and 1.2, 1848.2 the resolution was found to be 9.0.The linearity study for Meropenem and Vaborbactam was found in concentration range of 1μg-5μg and 100μg-500μg and correlation coefficient (r2) was found to be 0.999 and 0.999, % mean recovery was found to be 100.1% and 100.4%, %RSD for repeatability was0.31 and 0.38, % RSD for intermediate precision was 0.12 and 0.15 respectively. The precision study was precise, robust and repeatable. LOD value was 2.94 and 3.03, and LOQ value was 9.87 and 10.1 respectively.
Keywords: Meropenem, Vaborbactam, RP-HPLC

Cite This Article:

Please cite this article in press D.Vaishnavi et al, Method Development And Validation For Meropenemand Vaborbactam By RP-HPLC Method.., Indo Am. J. P. Sci, 2022; 09(12).

Number of Downloads : 10

References:

:

1. Overington JP, Al-Lazikani B, Hopkins AL: How many drug targets are there? Nat Rev Drug Discov. 2006 Dec;5(12):993-6.
2. Imming P, Sinning C, Meyer A: Drugs, their targets and the nature and number of drug targets. Nat Rev Drug Discov. 2006 Oct;5(10):821-34.
3. Castanheira M, Rhomberg PR, Flamm RK, Jones RN: Effect of the beta-Lactamase Inhibitor Vaborbactam Combined with Vaborbactam against Serine Carbapenemase-Producing Enterobacteriaceae. Antimicrob Agents Chemother. 2016 Aug 22;60(9):5454-8. doi: 10.1128/AAC.00711-16. Print 2016 Sep. (PubMed ID 27381386)
4. Lomovskaya O, Sun D, Rubio-Aparicio D, Nelson K, Tsivkovski R, Griffith DC, Dudley MN: Vaborbactam: Spectrum of Beta-Lactamase Inhibition and Impact of Resistance Mechanisms on Activity in Enterobacteriaceae. Antimicrob Agents Chemother. 2017 Oct 24;61(11). pii: AAC.01443-17. doi: 10.1128/AAC.01443-17. Print 2017 Nov. (PubMed ID 28848018)
5. Negi V, Chander V, Singh R, Sharma B, Singh P, Upadhaya K. Method development and validation of Vaborbactam in pharmaceutical dosage form by Rp-HPLC. Indian J ChemTechnol 2017;24:441-6.
6. Casals G, Hernandez C, Hidalgo S, Morales B, Lopez Pua Y, Castro P, et al. Development and validation of a UHPLC diode array detector method for Vaborbactam quantification in human plasma. Clin Biochem 2014; 47:223-7.
7. Ikawa K, Kameda K, Ikeda K, Morikawa N, Nakashima A, Ohge H, et al. HPLC method for measuring Vaborbactam and biapenem concentrations in human peritoneal fluid and bile: application to comparative pharmacokinetic investigations.J Chromatogr Sci 2010;48:406-11.
8. Kloft C, Wicha SG. Simultaneous determination and stability studies of linezolid, Vaborbactam and vancomycin in bacterial growth medium by high-performance liquid chromatography. J Chromatogr B 2016; 1028:242-8.
9. Lobenhoffer JM, Bode-Boger SM. Quantification of Vaborbactam in human plasma by HILIC–tandem mass spectrometry.J Chromatogr B 2017;1046:13-7.
10. Frenich AG, Reyes RC, Gonzalez RR, Maresca MA, Vidal JL. Simultaneous analysis of antibiotics in biological samples by ultra high performance liquid chromatography-tandem mass spectrometry. J Pharm Biomed Anal 2014;89:203-12.
11. Rigo Bonnin R, Ribera A, Arbiol Roca A, Cobo Sacristan S, Padulles A, Murillo O, et al. Development and validation of a measurement procedure based on ultra-high performance liquid chromatography-tandem mass spectrometry for simultaneous measurement of β-lactam antibiotic concentration in human plasma. Clin Chim Acta 2017;468:215-24.