Volume : 12, Issue : 02, February – 2025

Title:

REVIEW ON APPLICATIONS OF ICP-MS

Authors :

Purna Nagasree Kurre*, Raaga Sree Bade, Bala Krishna Konna, Jagadeesh Panda

Abstract :

The main uses, working principles and applications of Inductively coupled plasma – tandem mass spectrometry (ICP-MS/MS) are reviewed in this article. The primary distinctions between ICP-MS and single quadrupole ICP-MS are explained, along with the resources available for technique development. To illustrate the capabilities of this innovative setup in the context of elemental, speciation, and isotopic analysis, real-world examples are provided. It has applications in a wide range of research domains, including the food, material, chemical, semiconductor, and nuclear industries, as well as the earth, environmental, biological, and forensic sciences. All kinds of samples and matrices introduced by a range of specialised equipment find a suitable atomizer and element ioniser in the high ion density and high temperature of a plasma. Prominent characteristics include maximum sensitivity (ppt–ppq), relative salt resistance, element response independent of compound, and optimal quantitation precision contribute to ICP – MS’s unrivalled ability to effectively detect, identify, and consistently quantify trace elements. The molecular identification capabilities of ICP – MS hyphenated to species-specific separation techniques are expanded by the growing availability of pertinent reference compounds and good separation selectivity. ICP – MS is a productive and extremely sensitive technique for target-element oriented discoveries of relevant and unknown compounds, whereas molecular ion source MS is specialised in figuring out the structure of unknown molecules.
Keywords : ICP -MS, Applications, Principles, Sensitive, Characteristics.

Cite This Article:

Please cite this article in press Purna Nagasree Kurre et al Review On Applications Of ICP-MS.,Indo Am. J. P. Sci, 2025; 12 (02).

Number of Downloads : 10

References:

[1]. Carsten E. ICP – MS: Recent Trends and Developments. J. Anal. Bioanal. Chem. 2011. 399:213–219.
[2]. Houk RS. ICP – MS And European Discovery of America. J. Chem. Educ. 2000. 77:598-607.
[3]. Houk RS, Fassel VA, Flesch GD, Svec HJ, Gray AL, Taylor CE. Inductively Coupled Argon Plasma as an Ion source for Mass Spectrometric Determination of Trace Elements. Anal. Chem. 1980. 52:2283-2289.
[4]. Gray AL. It All Depends On The Source. Proc. Soc. Anal. Chem. 1974. 11:182-183.
[5]. Gray AL. Mass Spectrometric Analysis of Solutions Using An Atmospheric Pressure Ion Source. Analyst. 1975. 100:289-299.
[6]. Gray AL. Newer Aspects of Mass Spectrometry. Proc. Anal. Div. Chem. Soc. 1975. 12:94-95.
[7]. Gray AL. Plasma Sampling Mass Spectrometry for Trace Analysis of Solutions. Anal. Chem. 1975. 47:600-601.
[8]. Pozebon D, Scheffler G. L, Dressler V. L. Recent Applications of LA – ICP – MS for biological sample analysis : a follow-up review. J. Anal. At. Spectrom. 2017. 32:890-919.
[9]. Hao A. O. W, Daniel G, Charlotte G, Camelia N. B, James R. H. S.S, Bernd B, Detlef G. Fast Chemical Imaging At High Spatial Resolution by Laser Ablation ICP – MS. Anal. Chem. 2013. 85:10107-10116.
[10]. Marcel B, Alexander G. G, Steffen A, Gunnar S, Hao A. O. W, Luzia G, Simon B, Bodo H, Daniel G, Detlef G. High- speed, High – resolution, Multielemental LA – ICP- TOFMS Imaging : Part II. Anal Chem. 2015. 87:8250-8258.
[11]. Charlotte G, HAO A. O. W, Denis S, Nevena Z, Andrea J, Bodo H, Peter J. S, Daniel G, Joachim M. B, Simone B, Zsuzsanna V, Peter J. W, Detlef G, Bernd B. Highly Multiplexed imaging of Tumour Tissues with Subcellular Resolution by Mass Cytometry. Nat. Methods. 2014. 11:417-422.
[12]. Stijin J. M. V. M, Amy J. M, Barry L. S, Frank V. Recent Developments in The Design Of Rapid Response Cells for LA – ICP – MS and their Impact On Bioimaging Applications. J. Anal. A.t Spectrom. 2016. 31:423-439.
[13]. Alexander G. G, Detlef G. Toward faster and High Resolution LA – ICP – MS imaging. Anal Bioanal Chem. 2016. 408:2687-2695.
[14]. Adrian A. A. Inductively coupled plasma mass spectrometry (ICP – MS): a versatile tool. J. Mass Spectrom. 2007. 42:419–427.
[15]. John, W.O., Patrick, J.G. Considerations for measurement of individual nanoparticles or microparticles by ICP – MS : Determination of the number of particles and the analyte mass in each particle. J. Anal. At. Spectrom., 2012. 27:1143.
[16]. Bochert U. K, Dannecker W. On – Line Aerosol Analysis by Atomic Emission Spectroscopy. J. Aerosol Sci. 1989. 20:1525-1528.
[17]. Claude D, Favarger P. Y. (2003). Colloid Analysis by Single Particle ICP – MS. Colloids Surf. A. 217(1-3):137-142.
[18]. Carmen C. G, Ayrat M, Sebastian G, Vlasta H, Kay N. Characterization of Single Au and SiO2 Nano and Microparticles by ICP – OES using Monodisperse Droplets of Standard Solutions for Calibration. Anal. At. Spectrom. 2010. 25:645-653.
[19]. Yoshinari S, Hikaru S, Shimpei H, Kohei N, Naoki F. Real time Monitoring and Determination of Pb in a Single Airborne Nnaoparticle. J. Ana.l At. Spectrom. 2010. 25:947-949.
[20]. Bjorn M, Volker N. ICP – MS for the analysis at the nanoscale – a tutorial review.
J. Anal. At. Spectrom. 2018. 33:1432-1468.
[21]. Lieve B, Eduardo B. F, Martin R, Frank V. ICP – MS/MS : a powerful and universal tool for the interference – free determination of (ultra) trace elements – a tutorial review. Analytica Chimica Acta. 2015. 894:7.
[22]. Sakata K, Kawabata K. Reduction of Fundamental Polyatomic Ions in ICP – MS, Spectrochim. Acta B. 1994. 49:1027-1038.
[23]. Minnich M. G, Houk R. S. Comparison of Cryogenic and Membrane Desolvation for attenuation of Oxide, Hydride and Hydroxide Ions and Ions Containing Chlorine in ICP – MS. J. Anal. At. Spectrom. 1998. 13:167-174.
[24]. Jakubowski N, Prohaska T, Rottmann L, Vanhaecke F. ICP and Glow Discharge Plasma-Sector Field MS. J. Anal. At. Spectrom. 2011. 26:693-726.
[25]. Feldmann I, Jakubowski N, Stuewer D. Application of a Hexapole Collision and Reaction Cell in ICP-MS Part I. Fresenius J. Anal. Chem. 1999. 365:415-421.
[26]. Tanner S. D, Baranov V. I. Theory, Design, and Operation of a Dynamic Reaction Cell for ICP-MS. At. Spectrosc. 1999. 20:45-52.
[27]. Yamada N, Takahashi J, Sakata K. The Effects of Cell-Gas Impurities and Kinetic Energy Discrimination in an Octo-pole Collision Cell ICP-MS under Non-Thermalized Conditions. J. Anal. At. Spectrom. 2002. 17:1213-1222.
[28]. Vanhaecke F, Balcaen L, Malinovsky D. Use of Single-collector and Multi-collector ICP MS for Isotopic Analysis. J. Anal. At. Spectrom. 2009 24:863-886.
[29]. Kruger T. L, Litton J. F, Kondrat R. W, Cooks R. G. Mixture Analysis by Mass-Analysed Ion Kinetic-Energy Spectrometry. Anal. Chem. 1976 48:2113-2119.
[30]. Douglas D. J. Some Current Perspectives on ICP – MS. Can. J. Spectrosc, 1989. 34:38-49.
[31]. Yamada N. Kinetic Energy Discrimination in Collision ICP – MS: Theoretical Review of Principles and Limitations. Spectrochim. Acta B. 2015. 110:31-44.
[32]. Eduardo B. F, Lieve B, Martin R, Frank V. Overcoming Spectral Overlap via ICP – MS/MS. J. Anal. At. Spectrom. 2017. 32:1660-1679.
[33]. Kermit K. M, Robert K. B, Marcos N. E, John G. L, Liang L, Yasuhide N. Definitions of Terms Relating to Mass Spectrometry. Pure Appl. Chem. 2013. 85:1515-1609.
[34]. Zhaohui D, Terry N. O, Douglas D. J. ICP – MS with a Quadrupole Mass Filter Operated in Third Stability Region. J. Am. Soc. Mass Spectrom. 1997. 8:1230-1236.
[35]. Sergei F. B, Becket J. S. Improvement of Abundance Sensitivity in a Quadrupole based ICP – MS with a Hexapole Collision Cell. J. Anal. At. Spectrom. 2002. 17:1202-1206.
[36]. Blaum K, Geppert C. H, Muller P, Nortershauser W, Wendt K, Bushaw B. A. Peak shape for a Quadrupole MS. Int. J. Mass Spectrom. 2000. 202:81-89.
[37]. Theiner S, Loehr K, Koellensperger G, Mueller L, Jakubowski N. Single Cell Analysis by use of ICP – MS. J. Anal. At. Spectrom. 2020. 35:1784-1813.
[38]. Gschwind S, Flamingi L, Koch J, Borovinskaya O, Groh S, Niemax K, Gunther D. Capabilities of ICP – MS for the Detection of Nanoparticles Carried by Monodisperse Microdroplets. J. Anal. At. Spectrom. 2011. 26:1166-1174.
[39]. Degueldre C, Favarger P. Y. Colloid Analysis by Single Particle ICP – MS. Colloids Surf. A. 2003. 217:137-142.
[40]. Sharp B. L. Pneumatic Nebulisers and Spray Chambers for ICP – MS Part 2. J. Anal. At. Spectrom. 1988. 3:939-963.
[41]. Sharp B. L. Pneumatic Nebulisers and Spray Chambers for ICP – MS Part 1. J. Anal. At. Spectrom. 1988. 3:613-652.
[42]. Nomizu T, Kaneco S, Tanaka T, Ito D, Kawaguchi H, Vallee B. T. Determination of Ca Content in Individual Biological Cells by ICP Atomic Emission Spectrometry. Anal. Chem. 1994. 66:3000-3004.
[43]. Ho K. S, Chan W. T. Time resolved ICP – MS Measurement for Single – Cell Analysis and On – line Cytometry. J. Anal. At. Spectrom. 2010. 25:1114-1122.
[44]. Tsang C. N, Ho K. S, Sun H. Z, Chan W. T. Tracking Bi Antiulcer Drug Uptake in Single Helicobacter pylori Cells.. J. Am. Chem. Soc. 2011. 133:7355-7357.
[45]. Rodriguez M. C, Garcia R. A. F, Blanco E, Bettmer J, Bayon M. M. Quantitave Evaluation of Cisplatin uptake in Sensitive and Resistant Individual Cells by SC – ICP – MS. Anal. Chem. 2017. 89:11491-11497.
[46]. Merrifield R, Amable L, Stephan C. Single Cell ICP – MS Analysis: Quantifying the Metal Concentration of Unicellular Organisms at Cellular Level. Spectroscopy. 2018. 33:33-39.
[47]. Meyer S, Oliver A. S, Mitze H, Jakubowski N, Schwerdtle T.Single Cell Analysis by ICP – MS/MS as a Fast Tool for Cellular Bioavailability Studies of Arsentie. Metallomics. 2018. 10:73-76.
[48]. Shen X, Zhang H, He X, Shi H, Stephan C, Jiang H, Wan C, Eichholz T. Evaluating the Treatment Effectiveness of Cu based Algaecides on Toxic Algae Microcystis aeruginosa Using SC – ICP – MS. Anal. Bioanal. Chem. 2019. 411:5531-5543.
[49]. Virgilio A, Amais R. S, Amaral C. D. B, Fialho L. L, Schiavo D, Nobrega J. A. Reactivity and Analytical Performance of Oxygen as Cell Gas in ICP – tandem MS. Spectrochim. Acta. 2016. 126:31-36.
[50]. Goossens J, Vanhaecke F, Moens L, Dams R. Elimination of Interferences in the Determination As and Se in Biological Samples by ICP – MS. Anal. Chim. Acta. 1993. 280:137-143.
[51]. Darrouzes J, Bueno M, Lespes G, Gautier M. P. Optimisation of ICP – MS Collision. Talanta. 2007. 71:2080-2084.
[52]. Meyer S, Matissek M, Muller S. M, Taleshi M. S, Ebert F, Francesconi K. A, Schwerdtle T. In – vitro Toxicological Characterisation of Three As containing Hydrocarbons. Metallomics. 2014. 6:1023–1033.
[53]. Meyer S, Schulz J, Jeibmann A, Taleshi M.S, Ebert F, Francesconi K. A, Schwerdtle T. As containing Hydrocarbons are Toxic in In – vivo model Drosophila melanogaster. Metallomics. 2014. 6:2010-2014.
[54]. Balcean L, Woods G, Resano M, Vanhaecke F. Accurate Determination of S in Organic Matrices using Isotope Dilution ICP – MS. J. Anal. At. Spectrom. 2013. 28:33-39.
[55]. Wang X. X, Liu J. F, Wang X. Y, Shao B, Liu L. P, Zhang J. Direct Quantification of Total Sulphur Dioxide in Wine using Triple Quadrupole ICP – MS. Anal. Methods. 2015. 7:3224 – 3228.
[56]. Bishop D. P, Hare D. J, Fryer F, Taudte R. V, Cardoso B. R, Cole N, Doble P. A. Determination of Se in Serum in the Presence of Gadolinium with ICP – QQQ – MS. Analyst. 2015. 140:2842-2487.
[57]. Sugiyama N, Shikamori Y. Removal of Spectral Interferences on Noble Metal Elements using MS/MS Reaction Cell Mode of a Triple Quadrupole ICP -MS. J. Anal. At. Spectrom. 2015. 30:2481-2487.
[58]. Balcean L, Fernandez E. B, Resano M, Vanhaecke F. Accurate Determination of Ultra – Trace Levels in Ti in Blood Serum using ICP – MS/MS. Anal. Chim. Acta. 2014. 809:1-8.
[61]. Moens L. J, Vanhaecke F. F, Bandura D. R, Baranov V. I, Tanner S. D. Rb/Sr Age Determination of Magmatic Rocks. J. Anal. At. Spectrom. 2001. 16:991-994.
[62]. Nonose N, Ohata M, Narukawa T, Hioki A, Chiba K. Removal of Isobaric Interferences in Isotope Dilution Analysis of Vanadium in Silicon Nitride fine Ceramics Powder by DRC – ICP – MS. J. Anal. At. Spectrom. 2009. 24:310-319.
[63]. Zhao X, Koyanagi G. K, Bohme D. K. Reaction of Methyl Fluoride with Atomic Transition – Metal and Main – Group Cations: Gas – Phase room – Temperature Kinetics and Periodicities in Reactivity. J. Phys. Chem. A. 2006. 110:10607-10618.
[64]. Redondo P, Alvarez A. V, Rayon V. M, Largo A, Sordo J. A, Barrientos C. Reactivity of First – Row Transition Metal Monocations with Methyl Fluoride. J. Phys. Chem. A. 2013. 117:2932-2943.
[65]. Fernandez E. B, Balcean L, Resano M, Vanhaecke F. Interference Free Determination of Ultra Trace Concentrations of As and Se using Methyl Fluoride as a Reaction Gas in ICP – MS. Anal. Bioanal. Chem. 2015. 407:919-929.
[66]. Fernandez S. D, Encinar J. R, Medel A. S, Isensee D, Stoll H. M. Determination of Low B/Ca Ratios in Carbonates using ICP – QQQ. Geochem., Geophys., Geosyst. 2015. 16:2005-2014.
[67]. Amais R. S, Virgilio A, Schiavo D, Nobrega J. A. ICP – MS/MS for Overcoming Molybdenum Oxide Interferences on Cd Determination in Milk. Microchem. J. 2015. 120:64-68.
[68]. Machado R. C, Amaral C. D. B, Schiavo D, Obrega J. A. N, Nogueira A. R. A. Complex Samples and Spectral Inetrferences in ICP – MS. Microchem. J. 2017. 130:271-275.
[69]. Suoranta T, Bokhari S. N. H, Meisel T, Niemela M, Peramaki P. Elimination of Interferences in the Determination of Pa, Pl, Rh Mass Fractions in Moss Samples using ICP – MS/MS. Geostand. Geoanal. Res. 2016. 40:559-569.
[70]. Bamonti L, Theiner S, Udilova N. R, Keppler B. K, Koellensperger G. Accurate High Throughput Quantification of Se in Biological Samples – the Potential of Combining Isotope Dilution ICP – MS/MS with Flow Injection. J. Anal. At. Spectrom. 2016. 31:2227-2232.
[71]. Ohno T, Muramatsu Y, Shikamori Y, Toyama C, Okabe N, Matsuzaki H. Determination of Ultra Trace I129 in Soil Samples by Triple Quadrupole ICP – MS. J. Anal. At. Spectrom. 2013. 28:1283-1287.
[72]. Zheng J, Bu W, Tagami K, Shikamori Y, Nakano K, Uchida S, Ishii N. Determination of Cs135 and Cs137 Atomic Ration in Environmental Samples by Combining AMP. Anal. Chem. 2014. 86:7103-7110.
[73]. Yang G, Tazoe H, Yamada M. Improved Approach for Routine Monitoring of I129 and I127 Activity and Atomic Ratio in Environmental Samples using TMAH and ICP – MS/MS. Anal.Chim. Acta. 2016. 908:177-184.
[73]. Cao L, Zheng J, Tsukada H, Pan S, Wang Z, Tagami K, Uchida S. Simultaneous Determination of Radiocesium and Plutonium Isotopes in River Suspended Particles by ICP – MS/MS AND SF – ICP -MS. Talanta. 2016. 159:55-63.
[74]. Nelson J, Hopfer H, Silva F, Wilbur S, Chen J, Ozawa K. S, Wylie P. L. Evaluation of GC – ICP – MS/MS as a New Strategy for Specific Hetero – Atom Detection of P, S, Cl Determination in Foods. J. Agric. Food Chem. 2015. 63:4478-4483.
[75]. Klenesar B, Fernandez E. B, Florez M. R, Balcean L, Cuyckens F, Lynen F, Vanhaecke F. Determination of the Total Drug – Related Cl and Br contents in Human Blood Plasma using HPLC – ICP – MS/MS. J. Pharm. Biomed. Anal. 2016. 124:112-119.
[76]. Palcic J. D, Jones J. S, Flagg E. L, Donovan S. F. Lewisite Exposure Biomarkers in Urine by Liquid Chromatography – ICP – MS/MS with an accelerated Matrix – Matched Stability Study. J. Anal. At. Spectrom. 2015. 30:1799-1808.
[77]. Jackson B. P. Fast Ion Chromatography ICP – QQQ for As Speciation J Anal. At. Spectrom. 2015. 30:1405-1407.
[78]. Musil S, Petursdottir A. H, Raab A, Gunnlaugsdottir H, Krupp E, Feldmann J. Speciation without Chromatography using Selective Hydride Generation. Anal. Chem. 2014. 86:993-999.
[79]. Deitrich C. L, Cuello – Nunez S, Kmiotek D, Torma F. A, Busto M. E. del C, Fisicaro P, Goenaga H. I. Accurate Quantification of SEPP1 in Plasma using Isotopically Enriched Seleno-peptides and Species specific Isotopo Dilution with HPLC coupled to ICP – MS. Anal. Chem. 2016. 88:6357-6365.
[80]. Bishop D. P, Clases D, Fryer F, Williams E, Wilkins S, Hare D. J, Cole N, Karst W, Doble P. A. Elemental Bio – Imaging using Laser Ablation Quadrupole ICP – MS. J. Anal. At. Spectrom. 2016. 31:197-202.
[81]. Fernandez E. B, Malderen S. J. M, Balcean L, Resano M, Vanhaecke F. Laser ablation ICP – MS/MS for Direct Sr Isotopic Analysis of Solid Samples with Igh Rb/Sr ration. J. Anal. At. Spectrom. 2016. 31:464-472.
[82]. Andreas, L., Patrick, G., Maximillian, B., Gerald, B., Winfried, N., Frank, V. (2015). Recent advances in the quantitative LA – ICP – MS analysis : challenges and solutions in the life sciences and environmental chemistry. J. Anal Bioanal Chem., 2015, 407:6593–6617.
[83]. Qian, M., Zhiming, Y., Yueheng, Y., Zhuyin, C. (2023). Trace – element analysis and radiometric dating by inductively coupled plasma – tandem mass spectrometry : Approaches and applications to metallogeny. Ore Geology Reviews., 2023,163:105769.
[84]. Alessandra S, Julia S.B, Johanna S.B. Laser ablation ICP – MS: Application in Biomedical Research. J. Mass Spectrom. 2015. 36(1);47-57.